Thermal Analysis in UDEC

A thermal model comes standard in UDEC . This model simulates the transient flux of heat in materials and the subsequent development of thermally induced stresses. The heat flux is modeled by either isotropic or anisotropic conduction. Heat sources can be added and can be made to decay exponentially with time.

UDEC allows simulation of transient heat conduction in materials and the development of thermally induced displacements and stresses. This includes the following specific features.

  1. Heat transfer is modeled as conduction, either isotropic or anisotropic, depending on the user’s choice of material properties.
  2. Several different thermal boundary conditions may be imposed.
  3. Any of the mechanical block models may be used with the thermal model.
  4. Heat sources may be inserted into the material as volume sources. The sources may be made to decay exponentially with time.
  5. Both implicit and explicit calculations schemes are available, and the user can switch from one to the other at any time during a run.
  6. The thermal analysis provides one-way coupling to the mechanical stress calculation through the thermal expansion coefficient.
  7. The thermal analysis provides one-way coupling to the calculation for fluid flow in joints through the temperature dependency of fluid density and joint permeability.
Example

The following example shows a transient thermal-mechanical simulation of the behavior of a nuclear-waste emplacement drift in which heat-producing waste is placed vertically beneath the panel floor (Christianson, 1989). The emplacement drift under study is in the center of an emplacement panel. Waste canisters are placed in the floor of the drift. Using model symmetry, only one-half of the disposal room-and-pillar needs to be included in the analysis. The thermal boundary conditions are considered to be adiabatic.

The tributary heating area for the emplacement panel is reported to be 8194.5 m2. The average thermal loading is considered to be 14.1 W/m2. For the panel geometry, this results in an initial heat-generating power per meter of room length of 713.5 W. The initial power of a waste container at the time of emplacement varies from 0.42 kW to 3.2 kW. The following UDEC model shows the rock mass around the panel with the temperate distribution and thermal-induced rock displacements after 50 years since waste emplacement.

White lines around the panel indicates where joints have slipped.

UDEC Software Downloads

Latest News
  • WEBINAR: Solving Geothermal Challenges with XSite Numerical Modeling ITASCA Software and Baker Hughes are hosting a collaborative webinar to demonstrate how combining advanced...
    Read More
  • Itasca has announced the release of FLAC2D v9 Itasca has announced the release of FLAC2D v9, revolutionizing the way we analyze and predict...
    Read More
  • 6th Itasca Symposium on Applied Numerical Modeling The next Itasca Symposium will take place June 3 - 6, 2024, in Toronto, Canada....
    Read More

Upcoming Events
11 Aug
ITASCA Joins Caving 2026 as a Main Sponsor
We are pleased to announce that ITASCA will be participating as a Main Sponsor in Caving 2026, the leading international conference ded... Read More
15 Sep
ITASCA at EUROCK 2026: Advancing Innovation in Rock Engineering
ITASCA is pleased to announce its participation in EUROCK 2026 – ISRM Regional Symposium, taking place from 15–19 September 2026 in Sko... Read More
20 Sep
ITASCA to Participate in CouFrac 2026
ITASCA will be participating in CouFrac 2026, taking place from 20–23 September 2026 in Uppsala, Sweden. The conference brings together... Read More